CVE-2015-1417

Status Candidate

Overview

The inet module in FreeBSD 10.2x before 10.2-PRERELEASE, 10.2-BETA2-p2, 10.2-RC1-p1, 10.1x before 10.1-RELEASE-p16, 9.x before 9.3-STABLE, 9.3-RELEASE-p21, and 8.x before 8.4-STABLE, 8.4-RELEASE-p35 on systems with VNET enabled and at least 16 VNET instances allows remote attackers to cause a denial of service (mbuf consumption) via multiple concurrent TCP connections.

Related Files

FreeBSD Security Advisory - TCP Reassembly Resource Exhaustion
Posted Jul 28, 2015
Authored by Patrick Kelsey | Site security.freebsd.org

FreeBSD Security Advisory - There is a mistake with the introduction of VNET, which converted the global limit on the number of segments that could belong to reassembly queues into a per-VNET limit. Because mbufs are allocated from a global pool, in the presence of a sufficient number of VNETs, the total number of mbufs attached to reassembly queues can grow to the total number of mbufs in the system, at which point all network traffic would cease. An attacker who can establish concurrent TCP connections across a sufficient number of VNETs and manipulate the inbound packet streams such that the maximum number of mbufs are enqueued on each reassembly queue can cause mbuf cluster exhaustion on the target system, resulting in a Denial of Service condition. As the default per-VNET limit on the number of segments that can belong to reassembly queues is 1/16 of the total number of mbuf clusters in the system, only systems that have 16 or more VNET instances are vulnerable.

tags | advisory, denial of service, tcp
systems | freebsd
advisories | CVE-2015-1417
SHA-256 | 4651dfbd0c91abc16de434dacb94a6bbd086b3657240c2386bbf868ee0921266
Page 1 of 1
Back1Next

File Archive:

October 2024

  • Su
  • Mo
  • Tu
  • We
  • Th
  • Fr
  • Sa
  • 1
    Oct 1st
    39 Files
  • 2
    Oct 2nd
    23 Files
  • 3
    Oct 3rd
    18 Files
  • 4
    Oct 4th
    20 Files
  • 5
    Oct 5th
    0 Files
  • 6
    Oct 6th
    0 Files
  • 7
    Oct 7th
    17 Files
  • 8
    Oct 8th
    66 Files
  • 9
    Oct 9th
    25 Files
  • 10
    Oct 10th
    20 Files
  • 11
    Oct 11th
    21 Files
  • 12
    Oct 12th
    0 Files
  • 13
    Oct 13th
    0 Files
  • 14
    Oct 14th
    0 Files
  • 15
    Oct 15th
    0 Files
  • 16
    Oct 16th
    0 Files
  • 17
    Oct 17th
    0 Files
  • 18
    Oct 18th
    0 Files
  • 19
    Oct 19th
    0 Files
  • 20
    Oct 20th
    0 Files
  • 21
    Oct 21st
    0 Files
  • 22
    Oct 22nd
    0 Files
  • 23
    Oct 23rd
    0 Files
  • 24
    Oct 24th
    0 Files
  • 25
    Oct 25th
    0 Files
  • 26
    Oct 26th
    0 Files
  • 27
    Oct 27th
    0 Files
  • 28
    Oct 28th
    0 Files
  • 29
    Oct 29th
    0 Files
  • 30
    Oct 30th
    0 Files
  • 31
    Oct 31st
    0 Files

Top Authors In Last 30 Days

File Tags

Systems

packet storm

© 2024 Packet Storm. All rights reserved.

Services
Security Services
Hosting By
Rokasec
close