Secunia Security Advisory - A vulnerability has been reported in HP Tru64, which can be exploited by malicious, local users to gain escalated privileges.
fc0978bd5dfb0de9d690ed73e0a68856c678df2d2c33aadb3bb71b80dc28e140
----------------------------------------------------------------------
To improve our services to our customers, we have made a number of
additions to the Secunia Advisories and have started translating the
advisories to German.
The improvements will help our customers to get a better
understanding of how we reached our conclusions, how it was rated,
our thoughts on exploitation, attack vectors, and scenarios.
This includes:
* Reason for rating
* Extended description
* Extended solution
* Exploit code or links to exploit code
* Deep links
Read the full description:
http://corporate.secunia.com/products/48/?r=l
Contact Secunia Sales for more information:
http://corporate.secunia.com/how_to_buy/15/?r=l
----------------------------------------------------------------------
TITLE:
HP Tru64 libpthread "PTHREAD_CONFIG" Privilege Escalation
SECUNIA ADVISORY ID:
SA22743
VERIFY ADVISORY:
http://secunia.com/advisories/22743/
CRITICAL:
Less critical
IMPACT:
Privilege escalation
WHERE:
Local system
OPERATING SYSTEM:
HP Tru64 UNIX 5.x
http://secunia.com/product/2/
HP Tru64 UNIX 4.x
http://secunia.com/product/6/
DESCRIPTION:
A vulnerability has been reported in HP Tru64, which can be exploited
by malicious, local users to gain escalated privileges.
The vulnerability is caused due to a boundary error in libpthread
when handling the "PTHREAD_CONFIG" environment variable. This can be
exploited to cause a buffer overflow via a specially crafted data in
the variable.
Successful exploitation may allow execution of arbitrary code with
"root" privileges.
SOLUTION:
Apply ERP Kits.
HP Tru64 UNIX Version 5.1A PK6:
http://www2.itrc.hp.com/service/patch/patchDetail.do?patchid=T64KIT1000974-V51AB24-ES-20061031
MD5 Checksum: 5d61225e7bdbeed85b8f1a01153673c2
HP Tru64 UNIX Version 4.0G PK4:
http://www2.itrc.hp.com/service/patch/patchDetail.do?patchid=T64KIT1000976-V40GB22-ES-20061031
MD5 Checksum: c0cf54eaa49b6984e4ff515e965c63d2
HP Tru64 UNIX Version 4.0F PK8:
http://www2.itrc.hp.com/service/patch/patchDetail.do?patchid=DUXKIT1000975-V40FB22-ES-20061031
MD5 Checksum: 66c02c0b132b794d2b0888d0baefdaa6
PROVIDED AND/OR DISCOVERED BY:
Discovered by an anonymous person and reported via Netragard.
ORIGINAL ADVISORY:
HPSBTU02171 SSRT061222:
http://itrc.hp.com/service/cki/docDisplay.do?docId=c00800193
Netragard:
http://www.netragard.com/pdfs/research/HP-TRU64-LIBPTHREAD-20060811.txt
----------------------------------------------------------------------
About:
This Advisory was delivered by Secunia as a free service to help
everybody keeping their systems up to date against the latest
vulnerabilities.
Subscribe:
http://secunia.com/secunia_security_advisories/
Definitions: (Criticality, Where etc.)
http://secunia.com/about_secunia_advisories/
Please Note:
Secunia recommends that you verify all advisories you receive by
clicking the link.
Secunia NEVER sends attached files with advisories.
Secunia does not advise people to install third party patches, only
use those supplied by the vendor.
----------------------------------------------------------------------