NORTHERN TELECOM PRACTICE 297-1001-129

ISSUED: 93 09 29

RELEASE: 06.03 STANDARD































DIGITAL SWITCHING SYSTEMS



DMS*-100 FAMILY

INPUT/OUTPUT SYSTEM

REFERENCE MANUAL



















































* DMS is a trademark of Northern Telecom

Page 1

83 pages





PRACTICE 297-1001-129

RELEASE: 06.03











































































(c) Northern Telecom 1984-1987, 1990-1993





























Page 2





PRACTICE 297-1001-129

RELEASE: 06.03

CONTENTS

PAGE

1. INTRODUCTION . . . . . . . . . . . . . . . . . . . . . . 5



General . . . . . . . . . . . . . . . . . . . . . . . . 5

Practice Application . . . . . . . . . . . . . . . . . . 5

Reason for Reissue . . . . . . . . . . . . . . . . . . . 5

Software Identification . . . . . . . . . . . . . . . . 5

Command Format Conventions . . . . . . . . . . . . . . . 5

References . . . . . . . . . . . . . . . . . . . . . . . 7



2. INPUT/OUTPUT HARDWARE . . . . . . . . . . . . . . . . . 8

Input/Output Controller . . . . . . . . . . . . . . . . 9

Device Controllers . . . . . . . . . . . . . . . . . . . 9

IO User Classes . . . . . . . . . . . . . . . . . . . . 11



3. INPUT CONTROL SOFTWARE . . . . . . . . . . . . . . . . . 15



Remote Access Security Control . . . . . . . . . . . . . 15

Security and Access Control . . . . . . . . . . . . . . 15

Command Screening . . . . . . . . . . . . . . . . . . . 19

Show-Password Feature . . . . . . . . . . . . . . . . . 22

Dumpsafe State . . . . . . . . . . . . . . . . . . . . . 22
Priority Map Terminal . . . . . . . . . . . . . . . . . 22



4. OUTPUT CONTROL SOFTWARE . . . . . . . . . . . . . . . . 23



Log System Interface . . . . . . . . . . . . . . . . . . 23

SYSLOG . . . . . . . . . . . . . . . . . . . . . . . . . 25

Critical Message Prioritization . . . . . . . . . . . . 26

Guaranteed Background Schedule . . . . . . . . . . . . . 27

Secret Logs . . . . . . . . . . . . . . . . . . . . . . 27

Report Routing . . . . . . . . . . . . . . . . . . . . . 28

Report Thresholding . . . . . . . . . . . . . . . . . . 30

Thresholding for INIT and TRAP Logs . . . . . . . . . . 33
Log Format - Offices With Enhanced Core . . . . . . . . 33



5. MAN-MACHINE INTERFACE . . . . . . . . . . . . . . . . . 34



Types of MMI . . . . . . . . . . . . . . . . . . . . . . 34

Bilingual Man-Machine Interface . . . . . . . . . . . . 34

Parameters and Responses . . . . . . . . . . . . . . . . 35

Common Commands . . . . . . . . . . . . . . . . . . . . 35

Prompting . . . . . . . . . . . . . . . . . . . . . . . 35

Security and Access Control MMI . . . . . . . . . . . . 35

Command Screening MMI . . . . . . . . . . . . . . . . . 43

Report Routing MMI . . . . . . . . . . . . . . . . . . . 55
Search and Display (Browse) MMI . . . . . . . . . . . . 70



6. ABBREVIATIONS . . . . . . . . . . . . . . . . . . . . . 83











Page 3





PRACTICE 297-1001-129

RELEASE: 06.03

FIGURES



FIG. TITLE PAGE



1 Relationship of DMS-100 Family System to I/O Devices 10

2 Remote Access Security Control. . . . . . . . . . . . . 17

3 Security and Access Control Scheme. . . . . . . . . . . 18

4 Command Screening Scheme. . . . . . . . . . . . . . . . 21

5 Schematic Representation of Typical Log Buffer. . . . . 24

6 Report Routing Scheme. . . . . . . . . . . . . . . . . 32



TABLES



TABLE TITLE PAGE



A Common Parameters . . . . . . . . . . . . . . . . . . . 80

B Text of Common Command Responses . . . . . . . . . . . 81







































































Page 4





PRACTICE 297-1001-129

RELEASE: 06.03

1. INTRODUCTION





GENERAL



1.01 This Practice describes the hardware and software aspects

of the DMS-100 Family Input/Output (I/O) system. This

manual also contains details of the command syntax required to

execute the various I/O functions, and the machine responses that

occur as a result of these commands.



PRACTICE APPLICATION



1.02 The information contained in this Practice is applicable

to offices having Batch Change Supplement (BCS) 32 soft-

ware.



It is also applicable to offices having a BCS release greater

than BCS32 unless reissued. The application of all Northern

Telecom Practices (NTP) editions with respect to a given BCS

release is given in 297-1001-001.



REASON FOR REISSUE



1.03 This Practice has been reissued (06.03) to incorporate

minor changes to the log system interface description.





SOFTWARE IDENTIFICATION



1.04 Software applicable to a specific DMS-100 Family office is

identified by a BCS release number and by Northern Telecom

(NT) Product Engineering Codes (PEC). The significance of the

BCS number and the PEC is described in 297-1001-450 (section 32)
and in the Office Feature Record D-190.



1.05 A display of the BCS number and PEC for the NT feature

packages available in a specific office can be obtained by

entering the command string:



PATCHER;INFORM LIST;LEAVE



at a Maintenance and Administration Position (MAP).





COMMAND FORMAT CONVENTIONS

1.06 In this Practice, a uniform system of notation is used to

illustrate system commands and responses. It shows the

order in which command elements appear, the punctuation, and the

options. Where the conventions are not used, an explanation is

given in the text.





Page 5





PRACTICE 297-1001-129

RELEASE: 06.03

CAPITAL letters or show constants, commands, or keywords that

special characters the system accepts when entered as writ-

ten.



lowercase letters show a user- or system-supplied para-

meter. Definitions are given for each par-

ameter.



Brackets [ ] or enclose optional parameters. A vertical

list enclosed in brackets means that one

or more of the parameters may be selected.

Underlined parameter is a default. If no choice is entered, the

system acts as though the underlined para-

meter had been entered.



Underscore connecting means the words are to be treated as one

words item, for example, pm_type or #_one_two.



... indicates repeated steps or items.



In addition, the following conventions are used.



n (lowercase n) is a number from 0 to 9.

a (lowercase a) is a letter from A to Z.



h (lowercase h) is a hexadecimal integer from 0 to F.



1.07 Special features are implemented when the associated soft-

ware package is provisioned and installed. The following

features are available:



Feature In Package

Auto LOGIN NTX001

Bilingual Man-Machine Interface (BMMI) NTX066 Automatic
Dial Back NTX293

Critical Message Prioritization NTX001

Enhanced Command Screening NTX292

Guaranteed Background Schedule NTX000

MAP support for DISPLAYPHONE * NTX001

Password and Access Control NTX292

Priority MAP Terminal NTX001

Show Password (SHOWPW) Command NTX001

Secrecy NTX100

















1 * DISPLAYPHONE is a trademark of Northern Telecom.



Page 6





PRACTICE 297-1001-129

RELEASE: 06.03

REFERENCES



1.08 References listed as prerequisites are essential for an

understanding of this Practice. Those listed as inform-

ative contain detailed information concerning other items men-

tioned in this Practice, but are not essential. References are

inserted at the appropriate places in the text.



Note: The documents listed may exist in more than one version.

See 297-1001-001 to determine the release code of the version

compatible with a specific release of software.



Prerequisite References



DOCUMENT

NUMBER TITLE



297-1001-100 System Description





Informative References



NUMBER DOCUMENT TITLE



297-1001-001 Master Index of Practices

297-1001-110 Maintenance and Administration Position (MAP)

297-1001-310 Table Editor Reference Manual

297-1001-450 Provisioning

297-1001-451 Customer Data Schema

297-1001-455 The Office Parameters Reference Manual

297-1001-510 Log Report Manual

297-1001-516 Trunks Maintenance Reference Manual

GS1X55 Disk Drive Controller

GS1X67 GS1X61 Terminal Controller Card
Input-Output Controller

GS1X68 Magnetic Tape Controller Card



































Page 7





PRACTICE 297-1001-129

RELEASE: 06.03

2. INPUT/OUTPUT HARDWARE



2.01 Input/Output (I/O) hardware consists of various types of

controllers and I/O Devices (IOD) which enable the operat-

ing company to properly maintain, operate and administer the DMS

switch. This hardware is located in the maintenance and adminis-

tration area. (See 297-1001-100.)



2.02 The MAP (Maintenance and Administration Position) is the
2

primary device providing communication between the user

and the DMS switch. Through the MAP, the Man-Machine Interface

and display messages or reports. (See 297-1001-110 for details of
(MMI) is used to input commands, run tests, request information,

the MAP.)



2.03 In addition, full MAP support is provided for the DISPLAY-

PHONE terminal (F5439). The major difference between the

standard MAP position and the DISPLAYPHONE terminal is the line

editing control function, which is implemented using the cursor

movement keys and the control key sequences as follows:



Down Arrow causes the input line to be refreshed.



Up Arrow allows character insertion at the cursor position.

Right Arrow causes the cursor to advance one character position

to the right for each depression until the end of

the current input line is reached.



Left Arrow causes the cursor to back up one character position

to the left for each depression until the beginning

of the input line is reached.



CONTROL U this key sequence causes the contents of the input

line to be deleted (see Note).

CONTROL E this key sequence causes the input line from the

current cursor position to the end of the input line

to be deleted (see Note).



CONTROL X this key sequence turns off the effect of the Up

Arrow (see Note).



? retrieves the previous input line. The DMS remem-

bers the current and the two previous lines.



Note: The key sequence, CONTROL , means that the Con-

trol key is held down while the character is entered.

2.04 Other IOD are: printers, which can be used for MMI, and to

provide printed copies of reports; and magnetic tape or

disk recording devices, used for storage or retrieval of data.





2 MAP is a trademark of Northern Telecom



Page 8





PRACTICE 297-1001-129

RELEASE: 06.03

INPUT/OUTPUT CONTROLLER



2.05 The Input/Output Controller (IOC) is the hardware entity

which provides the interface between the Central Control

Complex (CCC) and the various types of IOD. (See Figure 1 on

page 10.) The CCC side of the IOC is connected via a pair of

32-channel, 2.56 Mb/s serial data links (designated DS30), to the

Central Message Controllers (CMC), and hence to the Central Proc-

essing Units (CPU) in the CCC.



2.06 Each of the two CMC has 70 serial data ports to which the

ports are assigned to the IOC, and others to the network message
DS30 data links are assigned in pairs. Some of these

controllers (NMC) in the two planes of the switching network.



2.07 Offices having BCS16 and higher software can have up to 12

pairs of ports assigned to links to up to 12 IOC (0 to

11). In this configuration, however, the number of pairs of

ports available for assignment to NMC is reduced to a maximum of

58. If less than 12 IOC are required, the number of ports avail-

able for assignment to NMC increases accordingly.



2.08 CMC port assignments to IOC and NMC are controlled by data

The format of the maintenance displays on the MAP, showing the
entered in the peripheral equipment assignment tables.

status of the IOC units, depends on which BCS release number is

in effect.



2.09 The other side of the IOC provides common parallel data

and address buses, to which up to nine (numbered 0 to 8)

Device Controllers (DC) are connected. The flow of data and its

routing to the addressed DC, is handled by the I/O message con-

troller.



2.10 Physically, the I/O message controller and the DC are cir-

The IOC shelves are housed in single-bay I/O equipment (IOE)
cuit cards which plug into the backplane of the IOC shelf.

frames. For more details of the IOC refer to GS1X61.





DEVICE CONTROLLERS



2.11 The DC converts the characteristics of the various IODs to

the common data bus format in the IOC. Three types of DC

circuit cards are required, and the number of each used depends

on the number of IOCs in service, and the number of IODs in use.

The provisioning of DC circuit cards forms part of the office

as follows: engineering process. The applications of the thre
e DC types are



* Disk Drive Controller (DDC) Interfaces the Disk Drive Unit

(DDU) with the IOC data bus. Enables the DDU to be con-

trolled by commands input at the MAP. Provides read/write

facilities for retrieval and storage of data on magnetic

disks. (See GS1X55 for details of the DDU.)



Page 9





PRACTICE 297-1001-129

RELEASE: 06.03





Program< > CPU < > Data

Store Store

(PS) A (DS)

DMS-100 Family

V CCC



CMC



A A A

To mate >To NMC

CMC and

CPU < DS30 >To other IOC





V V

I/O CONTROLLER SHELF

IO Message NT1X61

Controller

NT1X62

ADDRESS BUS

DATA BUS



0 6 7 8



DEVICE

CONTROLLERS TC . . . . . TC MTC DDC

(DC)



AA A A A A

0 .. 3 0 ... 3





EIA/ASCII

Interface MODEM V

DISK DRIVE UNIT

A

V

/ MAGNETIC TAPE DRIVE

MAP <

V V

Current Loop Interface

PRT REMOTE

PRINTER < I/O DEVICEV

DATAPAC or Datalink Devices





Fig. 1 - Relationship of DMS-100 Family System to I/O Devices







Page 10





PRACTICE 297-1001-129

RELEASE: 06.03

* Magnetic Tape Controller (MTC) Interfaces the Magnetic Tape

Drive (MTD) with the IOC data bus. Enables the MTD to be

controlled by commands input at the MAP. Provides read/write

facilities for retrieval and storage of data on magnetic

tapes. (See GS1X68 for details of the MTC.)



* Terminal Controller (TC) The TC are multi-purpose circuit

cards which interface up to four IOD per card with the IOC

data bus. The four ports to which IOD are connected can have

their configurations set to match the characteristics of the

IOD connected to that port. (See GS1X67 for more details of

the TC.) Port configurations are programmable, and are set
by entries in table TERMDEV to either of the following con-

figurations:



EIA/ASCII used for IOD (MAP or PRT) located within 50 ft

(15m) of the IOE frame; also to connect to a modem for

operation with remote devices.



Current Loop used for IOD located within 1200 ft (366m)

of the IOE frame.



2.12 The proper DC for each type of IOD is assigned by data

istics such as baud rate, port configuration, etc. are also
entered in the appropriate IOD table. Other character-

assigned in these tables.



2.13 IO devices and their associated data tables are as fol-

lows:



* Magnetic Tape Drives - table MTD

* Disk Drive Units - table DDU

* Visual Display Unit - (part of MAP), printers (PRT), or modem

3 to a remote PRT - table TERMDEV

* DATAPAC - table DPACDEV

* Data Link Controller - DLCDEV.



IO USER CLASSES



2.14 IO users should be organized into classes which define a

specific set of functions that these users are required to

perform. These functional needs in turn dictate the IOD require-

ments for each user class. The actual organization of I/O user

classes is completely flexible to meet operating company opera-

tional requirements. The general principle is that the division

of tasks shall serve the purpose of each user class, yet will

ensure that they do not interfere with each other's functions.

2.15 The selection of the type and quantity of IOD for each

user-class function depends on operating company require-







3 DATAPAC is a trademark of Bell Canada



Page 11





PRACTICE 297-1001-129

RELEASE: 06.03

ments, and forms part of the office engineering process. Infor-

mation on the provisioning is contained in 297-1001-450.



2.16 Following are the names and descriptions for some typical

I/O user classes:



Administration (ADMIN): provides the user with unlimited

access from any IOD to all command classes (see PRIVCLAS),

and in addition is assigned the highest priority level (see

PERMIT). The password associated with ADMIN cannot be dis-

played, and cannot be changed by any other user (see COMMAND

SCREENING).




Login or Register to add favorites

File Archive:

September 2024

  • Su
  • Mo
  • Tu
  • We
  • Th
  • Fr
  • Sa
  • 1
    Sep 1st
    261 Files
  • 2
    Sep 2nd
    17 Files
  • 3
    Sep 3rd
    38 Files
  • 4
    Sep 4th
    52 Files
  • 5
    Sep 5th
    23 Files
  • 6
    Sep 6th
    27 Files
  • 7
    Sep 7th
    0 Files
  • 8
    Sep 8th
    1 Files
  • 9
    Sep 9th
    16 Files
  • 10
    Sep 10th
    38 Files
  • 11
    Sep 11th
    21 Files
  • 12
    Sep 12th
    40 Files
  • 13
    Sep 13th
    18 Files
  • 14
    Sep 14th
    0 Files
  • 15
    Sep 15th
    0 Files
  • 16
    Sep 16th
    21 Files
  • 17
    Sep 17th
    51 Files
  • 18
    Sep 18th
    23 Files
  • 19
    Sep 19th
    48 Files
  • 20
    Sep 20th
    0 Files
  • 21
    Sep 21st
    0 Files
  • 22
    Sep 22nd
    0 Files
  • 23
    Sep 23rd
    0 Files
  • 24
    Sep 24th
    0 Files
  • 25
    Sep 25th
    0 Files
  • 26
    Sep 26th
    0 Files
  • 27
    Sep 27th
    0 Files
  • 28
    Sep 28th
    0 Files
  • 29
    Sep 29th
    0 Files
  • 30
    Sep 30th
    0 Files

Top Authors In Last 30 Days

File Tags

Systems

packet storm

© 2024 Packet Storm. All rights reserved.

Services
Security Services
Hosting By
Rokasec
close