TITLE:
Symantec Firewall Devices SMTP Binding Configuration Bypass
SECUNIA ADVISORY ID:
SA14428
VERIFY ADVISORY:
http://secunia.com/advisories/14428/
CRITICAL:
Less critical
IMPACT:
Exposure of sensitive information
WHERE:
>From remote
OPERATING SYSTEM:
Symantec Firewall/VPN Appliance 100/200/200R
http://secunia.com/product/552/
Symantec Gateway Security 2.x
http://secunia.com/product/3104/
Symantec Nexland Firewall Appliances 1.x
http://secunia.com/product/4466/
DESCRIPTION:
Arthur Hagen has reported a security issue in various Symantec
firewall devices, which may disclose sensitive information to
malicious people.
The problem is caused due to an error in the SMTP binding
functionality of certain devices with ISP load-balancing
capabilities. This results in outbound email traffic being
load-balanced regardless of the configured WAN binding selection,
which may cause sensitive SMTP traffic only destined for a trusted
network to be passed over an untrusted connection.
The security issue has been reported in the following versions:
* Symantec Firewall/VPN Appliance 200/200R (firmware builds prior to
build 1.68 and later than 1.5Z)
* Symantec Gateway Security 360/360R (firmware builds prior to build
858)
* Symantec Gateway Security 460/460R (firmware builds prior to build
858)
* Nexland Pro800turbo (firmware builds prior to build 1.6X and later
than 1.5Z)
SOLUTION:
The vendor has issued updated firmware releases.
http://www.symantec.com/techsupp
Symantec Firewall/VPN Appliance models 200 and 200R:
Update to build 1.68.
Symantec Gateway Security Appliance 300 and 400 series:
Update to build 858.
Nexland Pro800turbo:
Update to build 1.6X.
PROVIDED AND/OR DISCOVERED BY:
Arthur Hagen
ORIGINAL ADVISORY:
http://securityresponse.symantec.com/avcenter/security/Content/2005.02.28.html
----------------------------------------------------------------------
About:
This Advisory was delivered by Secunia as a free service to help
everybody keeping their systems up to date against the latest
vulnerabilities.
Subscribe:
http://secunia.com/secunia_security_advisories/
Definitions: (Criticality, Where etc.)
http://secunia.com/about_secunia_advisories/
Please Note:
Secunia recommends that you verify all advisories you receive by
clicking the link.
Secunia NEVER sends attached files with advisories.
Secunia does not advise people to install third party patches, only
use those supplied by the vendor.
----------------------------------------------------------------------