Chapter 2:


DS30 link maintenance


Purpose


The DS30 link maintenance facilities are available on the DMS-SCP transaction
processor terminal. Link maintenance allows a service control point (SCP) user
to monitor, test, and alter the states of DS30 links that extend between the
transaction processor DVS cabinets and DMS common equipment.


The link can be monitored at two levels of detail, the link summary level and
the link detail level. There are also two modes in which to conduct a link
test. The link can be tested in an in-service (INSV) mode or in an
out-of-service (OOS) mode.


The state of the link can be altered, in fact must be altered to conduct some
tests. Links can be manually busied, returned to an in-service state and under
some conditions taken off-line.


Note: A strict set of procedures must be executed before a link can be taken
off-line. For instructions refer to the heading, "Taking a Link Off-line" found
later in this chapter.


Accessing the DS30 maintenance screen


To access the DS30 link maintenance screen, use the following procedure:


1 Sign in to a DMS-SCP terminal, using a system administrator user ID. Refer to
the chapter entitled "Signing In" found earlier in this publication for sign in
procedures.


==> The DMS-SCP main menu is displayed.


2 Select the DS30 link maintenance option from the main menu, and press ENTER.


==> The DS30 link status screen as shown in Figure 1 is displayed. This screen
provides a summary of the status of all links.


Figure 1
Screen interactions for DS30 SRU maintenance
<See Fig. 1>

Monitoring link & application summaries


A total of 28 DS30 SRUs may be viewed using the DS30 Mtce screen on two TPs for
a single SCP installation. Each DS30 SRU runs a single database or system
application and is connected to the DMS component of the TP by two links. The
link and application summary screen provides status information for each link
and for each application the link is connected to. The location of the SRU (and
link connection) is also given.


Interpreting the screen


The link summary screen is divided vertically. Each side identifies 10 DS30 SRU
locations and reports on the status of both links connected to and the
application running on each. (If more than 20 DS30 SRUs are configured, they
are listed on the next page.) Information is listed in columns under the
following headings:


(a) L.meaning local area network (LAN) identifies the transaction processor in
which the SRU resides. An SRU can only reside in TP 1 or TP 2.


(b) C. identifies the TP cabinet in which the SRU resides. An SRU can reside in
one of eight cabinets, numbered 1 - 8.



PAGE


(c) S. identifies the cabinet slot address at which the SRU resides. An SRU
address can be one of 16, numbered evenly from 2 - 16.


(d) L0, L1. identifies the status of link 0 and link 1 in separate columns
using a single symbol or character. The meaning of the symbols and characters
used is given below:

ÚÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄ¿
³w = In Service The link is working. ³
³ÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄij
³M = Manual - Busy The link has been made busy through manual ³
³ intervention. ³
³ÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄij
³S = System - Busy The link is ready to return to service but cannot ³
³ because of system conditions. ³
³ÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄij
³O = Offline The link is offline and not communicating. ³
³ÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄij
³H = Unequipped The link is encountering a hardware problem, or ³
³ the link is not yet aware of the SRU (following an ³
³ SRU reboot). ³
³ÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄij
³T = Testing The link is being tested. ³
³ÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄij
³? = No link Info The link has registered but has not yet sent ³
³ information to the database control program. When ³
³ the whole SRU is down the link responds with this ³
³ state. ³
ÀÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÙ


(e) APPLICATION. identifies the application, the application instance, and the
state of the application running in the SRU.


The application name is followed a number ranging from 1-20. This number
identifies the instance, that is, the particular TP copy of the application
running in the SRU. (There may be several copies of each database in a single
transaction processor.) An * signifies that the application is used as a
backups.


The state precedes the name of the application and is represented by a symbol
or a single character explained below:

ÚÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄ¿
³w = In Service The application is working. ³
³ÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄij
³B = Busy The application is busy. ³
³ÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄij
³C = Congested The application is too busy and is trying to ³
³ correct the condition by limiting the number of ³
³ queries it is sent. ³
³ÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄij
³F = Failed The application has stopped working. ³
³ÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄij
³A = Audit The application is disabled due to a volume audit. ³
³ÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄij
³=Unknown The application configured but has not yet come ³
³ up. ³
³ÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄij
³= None No application is configured on the SRU. ³
ÀÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÙ


Monitoring link & application detail


The link details area is displayed on the lower portion of the link summary
screen for a single selected SRU. Link detail information duplicates link
summary information but presents it in a horizontal format. This screen does
provide additional information in the form of test data and application
specific data.


Access


To display further details for a specific DS30 link, use the following
procedure:


1 Select an SRU to examine by highlighting it. Use arrow keys to move the
highlighted bar.


2 Press the <Details> softkey.


==> The details display appears at the bottom of the screen. Figure 1
illustrates a typical link details display.


3 To display details of another link, move the cursor up or down using the
arrow keys until the required link is highlighted.


==> The link details of the previously selected SRU are retired as soon as the
highlighted bar is moved.



PAGE


4 Press <Details> again.


==> The details of the newly selected SRU are displayed.


Interpreting the screen


The link and application details display consists of an expanded version of the
link and application summary area plus the following: test data, application
PRU type and subsystem instance (SSI).


Test data is presented under the following headings:


(a) TEST EXECUTED AT. Below this heading the date and time of the last test
conducted on both link 0 and link 1 for the selected SRU is specified.


(b) OOS & INSV. These headings identify the two available test modes, OOS, or
INSV. An entry below one of these headings indicates the modes and the results
of the test conducted. Test results are represented by one of the following
single character entries:

ÚÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄ¿
³P = Passed ³
³ÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄij
³F = Failed ³
³ÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄij
³blank = Test not run ³
ÀÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÙ


Additional application related-data is presented under the following headings:


(a) SSI. This heading refers to the subsystem instance. If the entry is INSV
meaning in-service, the link can transmit responses to the DMS, if the entry is
OOS, meaning out-of-service, the link cannot transmit responses to the DMS.


(b) PRU. This heading identifies the PRU running in the SRU by type. This entry
is a four digit hexadecimal number.


Testing DS30 links


DS30 links between DVS and DMS equipment should be tested on a weekly basis as
part of a maintenance routine. Testing is conducted in one of two modes,
out-of-service or in-service. Testing can only be done when the link is in one
of the states:


w in-service or


w manual busy.


When problems arise, the administrator tests as required and uses the most
appropriate test at that time. An out-of-service test is used if the links
cannot be brought up. An in-service test is used when logs are reporting link
errors that are not fatal.


System messages


System messages provide important information to the user during the test
situation. Messages are displayed across the top of the screen. Test result
words may appear in a system message. Table 3 specifies the meanings of these
test result words:


Table 3
DS30 maintenance test result words

ÚÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄ¿
³RESULT WORD SIGNIFICANCE ³
³ÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄij
³Rejected (T) Only one maintenance or test request is allowed per SRU, and this result ³
³ indicates that a request is already in progress, most likely from another ³
³ DMS-SCP. ³
³ÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄij
³Unsupported The maintenance or test request specified is unsupported. ³
³ÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄij
³Invalid (SRU) The SRU specified in the maintenance or test request has become invalid since ³
³ the request was initiated. ³
³ÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄij
³ ³
ÀÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÙ

PAGE


ÚÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄ¿
³In Progress The test is in progress and will report back with a result later. ³
³ÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄij
³Rejected (S) The maintenance or test request cannot be performed because the resulting ³
³ state transition would be invalid such as attempting to OFFL a link which is ³
³ in a system busy state. ³
³ÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄij
³Failed The test has failed. ³
³ÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄij
³Completed The test has been completed, and the information in the link summary and ³
³ detail areas of the display should not reflect any changes as a result of the ³
³ successful maintenance or test request. ³
ÀÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÄÙ


Out-of-service testing


To conduct an out-of-service test use the following procedure:


1 Select an SRU from the link and application summary screen, and press
<Details>.


==> The link and application details area is displayed at the bottom of the
summary screen.


2 Press <MANB>.


==> The following softkeys are displayed: <Cancel>, <Link 0>, and <Link 1>.


3 Press <Link 0> to select link 0, press <Link 1> to select link 1 or press
<Cancel>.


==>When link 0 or link 1 softkeys are pressed the state of the selected link
changes to M, meaning manual busy.
==> When the cancel softkey is pressed, the manual busy request is cancelled.


4 Press <Test>.


==> The following softkeys are displayed: <Cancel>, <Link 0>, and <Link 1>.


5 Press <Link 0> to test link 0, press <Link 1> to test link 1 or press
<Cancel>.


==>When either the link 0 or link 1 softkey is pressed the test is executed.
While the test is running, the link state displayed is T, meaning testing. When
the test is finished, the link is returned to the manbusy state, and the status
of the test is reported on the display.
==> When the cancel softkey is pressed, the test is cancelled but the state of
the selected SRU links remain manual busy.


In-service testing


To conduct an in-service test use the following procedure:


1 Select an SRU from the link and application summary screen, and press
<Details>.


==> The link and application details area is displayed at the bottom of the
summary screen.


2 Press <Test>.


==> The following softkeys are displayed: <Cancel>, <Link 0>, and <Link 1>.


3 Press <Link 0> to test link 0, press <Link 1> to test link 1 or press
<Cancel>.


==>When link 0 or link 1 softkeys are pressed the test is executed, the
softkeys retire, and the status of the test is reported on the display.When the
test is finished, the link is returned to the system busy state and, if
possible, will eventually return to an in service state.
==> When the cancel softkey is pressed, the test is cancelled.


Making links busy and returning them to service


The links associated with each SRU can be manually busied (MANB). Links must be
in a busy state in order to run out-of-service tests. In this state, the
application cannot process queries or otherwise communicate with the DMS. To
restore communication

PAGE


with the DMS, the links and the application must be returned to service. Only
links in a manual busy state can be returned to service.


Manual busy


Use the following procedure to manual busy a link:


1 Select the SRU whose links need to be placed into a manual busy state. Do
this by highlighting the SRU on the link and application summary screen.


2 Press <MANB>.


==> The following softkeys are displayed: <Cancel>, <Link 0>, and <Link 1>.


3 Press <Link 0> to manual buys link 0, press <Link 1> to manual busy link 1 or
press <Cancel>.


==>When link 0 or link 1 softkeys are pressed the state of the selected link
changes to M, meaning manual busy.
==> When the cancel softkey is pressed, the manual busy request is cancelled.


Return to service


Use the following procedure to return a link to service:


1 Select an SRU with manual busy links that need to be returned to service. Do
this by highlighting the SRU on the link and application summary screen.


2 Press <RTS>.


==> The following softkeys are displayed: <Cancel>, <Link 0>, and <Link 1>.


3 Press <Link 0> to RTS link 0, press <Link 1> to RTS link 1 or press <Cancel>.


==>When link 0 or link 1 softkeys are pressed the state of the selected link
changes to S, meaning system busy. The link stays in the system busy state
until the next link audit, when it changes to a dot meaning inservice.
==> When the cancel softkey is pressed, the manual busy request is cancelled.


Taking a link offline


A link can be taken offline if there are SRU hardware problems. There is a set
of procedures for taking a link offline that must be followed to ensure the
integrity of the system.


To take a link offline use the following procedure:


1 On the link and application summary screen, note the SRU location of the link
that needs to be taken offline. This information is found under the L, C and S
headings.


2 Press <Exit> until the main menu for the DMS-SCP transaction processor is
displayed.


3 Select the system administration option, and press ENTER.
Select the maintenance option.
Locate the cabinet and slot of the SRU to which the links are connected. This
is the same address noted in procedure 1.


4 Highlight the DBTM at this location, and then press <Courtesy Down>.


==> The system takes the PRU out-of-service. In the process of taking the PRU
out-of-service, the DBTM informs the Data-Voice interface (DVI) that queries
should not be routed to this SRU. The courtesy down process ensures that all
outstanding queries are processed before the PRU is shut down.


5 Return to the DS30 link and application summary screen.



PAGE


6 Highlight the SRU address where the DBTM has been courtesied down, and then
press <OFFL>.


==> The following softkeys are displayed: <Cancel>, <Link 0>, and <Link 1>.


7 Press <Link 0> to offline link 0, press <Link 1> to offline link 1 or press
<Cancel>.


==>When link 0 or link 1 softkeys are pressed the state of the selected link
changes to O, meaning offline.
==> When the cancel softkey is pressed, the offline request is cancelled.


Returning service to the offline link


Return service to the offline link using the following procedure:


1 Make the offline links manual busy by highlighting the effected links and
pressing <MANB>. (Follow the manual busy procedure given earlier.)


2 Return the effected DBTM to service from SAS. (Follow step 3 of the previous
procedure.)


3 Return the links to service by highlighting the manually busied links and
pressing <RTS>. (Follow the RTS procedure given earlier.)



Login or Register to add favorites

File Archive:

April 2024

  • Su
  • Mo
  • Tu
  • We
  • Th
  • Fr
  • Sa
  • 1
    Apr 1st
    10 Files
  • 2
    Apr 2nd
    26 Files
  • 3
    Apr 3rd
    40 Files
  • 4
    Apr 4th
    6 Files
  • 5
    Apr 5th
    26 Files
  • 6
    Apr 6th
    0 Files
  • 7
    Apr 7th
    0 Files
  • 8
    Apr 8th
    22 Files
  • 9
    Apr 9th
    14 Files
  • 10
    Apr 10th
    10 Files
  • 11
    Apr 11th
    13 Files
  • 12
    Apr 12th
    14 Files
  • 13
    Apr 13th
    0 Files
  • 14
    Apr 14th
    0 Files
  • 15
    Apr 15th
    30 Files
  • 16
    Apr 16th
    10 Files
  • 17
    Apr 17th
    22 Files
  • 18
    Apr 18th
    45 Files
  • 19
    Apr 19th
    0 Files
  • 20
    Apr 20th
    0 Files
  • 21
    Apr 21st
    0 Files
  • 22
    Apr 22nd
    0 Files
  • 23
    Apr 23rd
    0 Files
  • 24
    Apr 24th
    0 Files
  • 25
    Apr 25th
    0 Files
  • 26
    Apr 26th
    0 Files
  • 27
    Apr 27th
    0 Files
  • 28
    Apr 28th
    0 Files
  • 29
    Apr 29th
    0 Files
  • 30
    Apr 30th
    0 Files

Top Authors In Last 30 Days

File Tags

Systems

packet storm

© 2022 Packet Storm. All rights reserved.

Services
Security Services
Hosting By
Rokasec
close